BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Suwanu - ECPv5.7.0//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Suwanu
X-ORIGINAL-URL:https://suwanu-europe.eu
X-WR-CALDESC:Events for Suwanu
BEGIN:VTIMEZONE
TZID:Europe/Madrid
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0100
TZNAME:CET
DTSTART:20500101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20500604
DTEND;VALUE=DATE:20500605
DTSTAMP:20260820T161435
CREATED:20191104T144407Z
LAST-MODIFIED:20191108T075506Z
UID:8165-2537913600-2537999999@suwanu-europe.eu
SUMMARY:Production and use of Waters for Reuse (ApR) in Alentejo irrigation
DESCRIPTION:Production and use of Waters for Reuse (ApR) in Alentejo irrigation\n\n		\n	\n\n	\n		\n			REUSE\n\n		\n	\n\n	\n		\n			 \nWaste water source\nThe urban wastewater comes from the WWTP of Beja (Alentejo). \n\n		\n	\n\n	\n		\n			 \nDistribution System\nThis distribution system consists in one mainline and one container. \n\n		\n	\n\n	\n		\n			 \nFarming system\nA pomegrate tree orchard recieves reclaimed water by drip irrigation. \n\n		\n	\n\n	\n		\n			 \nWaste water treatment description\nNutrient removal : Solar concentrators are being used to firstly disinfect the water. But in some tests there was an overall improvement in the quality of the treated effluent\, transmittance and COD.\nPesticide removal : none\nDisinfection : In the REUSE project\, the Beja WWTP pilot case is testing disinfection with solar technology. Concentrating panels of the solar radiation for disinfection by action of UV radiation and thermal action.\nSuspended solids removal : Suspended solids are removed by filtration.\nOther \n\n		\n	\n\n	\n		\n			 \nCapacity\nThe capacity of the WWTP 32\,750 equivalent inhabitants\, which corresponds in this case to about 4\,830 m³/day. The experimental disinfection unit reaches a flow rate of 5 m³/day. \n\n		\n	\n\n	\n		\n			 \nExtent of the agricultural beneficiaries\nOne farm (with pomegranate orchards) is irrigated with reclaimed water within the framework of a demonstration pilot of 0.5 ha. \n\n		\n	\n\n	\n		\n			 \nCosts\nFunding is done by Fundo Ambiental. The cost of the reclaimed water is yet unknown. \n \n\n		\n	\n\n	\n		\n			 \nType of agreement\n\n		\n	\n\n	\n		\n			 \nScientific results\nFollowing results have been found out of the projects own research: \n-The feasibility of using solar equipment in tests for solar disinfection of urban wastewater for irrigation purposes was verified. \n- Laboratory and pilot tests have achieved load reduction values consistent with the quality objectives required for practical use. \n- High synergistic effect on wastewater disinfection with UVA and UVB radiation\, and the infrared radiation that increases the water temperature\, accelerating the disinfection process. \n- The temperatures reached through the panels have considerably reduced the disinfection times required. \n\n		\n	\n\n	\n		\n			 \nAdditional information\n- REUSE concerns a demonstration pilot for reclaiming water using technologies of treatment to reduce operational cost and increase its use in the irrigation activity.\n- Installation of a demonstration pilot at the interface of urban wastewater treatment infrastructures with irrigation infrastructures to clarify the dynamics of the barriers created by the dilution and transport of the water to the irrigation perimeter.\n- Promotion of a communication and awareness campaign for the need to promote water use efficiency in the irrigation activity and demonstration of success cases in the reuse of water in this economic activity. \nPDF (Spanish):\nhttps://suwanu-europe.eu/wp-content/uploads/2019/11/24_Apresentacoes_ConfAguaNovasAbordagens_reduce-12_25_2.pdf
URL:https://suwanu-europe.eu/project/reuse-alentejo/
LOCATION:Portugal
CATEGORIES:Initiative
ATTACH;FMTTYPE=image/png:https://suwanu-europe.eu/wp-content/uploads/2019/11/REUSE-1.png
GEO:38.015015;-7.863156
END:VEVENT
END:VCALENDAR